NRC RATING FOR CORNER SOLUTIONS
NOISE REDUCTION COEFFICIENT (NRC) |
Acoustical foam's effectiveness is measured by its Noise Reduction Coefficient, or NRC rating. The NRC of a material can be found by using either the Reverberation Room Method (ASTM C423) or the Impedance Tube Method (ASTM C384). We use the Reverberation Room Method. |
| 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | Overall | |
| Corner Bass Absorbers | 1.18 | 1.27 | 1.26 | 1.19 | 1.16 | 1.16 | 1.20 |
| Male Broadband Absorbers | 0.52 | 0.78 | 1.00 | 0.93 | 1.01 | 1.07 | 0.95 |
| Female Broadband Absorbers | 0.59 | 0.88 | 0.95 | 0.95 | 1.06 | 1.07 | 0.95 |
NOTE: Testing for the NRC Rating was done by the Reverberation Room Method (ASTM C423)
For individual testing results, please click the corresponding link below:
Corner Bass Absorber
Male Broadband Absorber
Female Broadband Absorber
For our product performance comparison report
Comparison Report