NRC RATING FOR WEDGE FOAM
NOISE REDUCTION COEFFICIENT (NRC) |
Acoustical foam's effectiveness is measured by its Noise Reduction Coefficient, or NRC rating. The NRC of a material can be found by using either the Reverberation Room Method (ASTM C423) or the Impedance Tube Method (ASTM C384). We use the Reverberation Room Method. |
| 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | Overall | |
| 1" Wedge | 0.14 | 0.17 | 0.36 | 0.47 | 0.51 | 0.61 | 0.40 |
| 2" Wedge | 0.20 | 0.29 | 0.66 | 0.80 | 0.89 | 1.02 | 0.65 |
| 3" Wedge | 0.25 | 0.47 | 0.83 | 0.82 | 0.92 | 1.04 | 0.75 |
| 4" Wedge | 0.39 | 0.61 | 0.91 | 0.79 | 0.95 | 1.03 | 0.80 |
NOTE: Testing for the NRC Rating was done by the Reverberation Room Method (ASTM C423)
For individual testing results, please click the corresponding link below:
1 Inch Wedge Foam
2 Inch Wedge Foam
3 Inch Wedge Foam
4 Inch Wedge Foam
For our product performance comparison report
Comparison Report